Patch-clamp data
Igor Pro (WaveMetrics) is the default supported software: its .ibw and
.pxp files are read directly, with units, sample interval and wave notes.
This covers SutterPatch, which runs inside Igor Pro. Data from other
acquisition software can be imported as .csv or .txt.
Patch-clamp waveforms come in through two menu entries:
| Menu | Imports | Into |
|---|---|---|
| File → Import data → Input → Patch Clamp | Command waveforms (input) | Input arrays |
| File → Import data → Output → Patch Clamp | Recordings (voltage in current clamp, current in voltage clamp) | Trace data (and spike data) |
File formats
.ibw: Igor Binary Wave. 1-D waves, or 2-D samples × sweeps waves, whose sweeps are joined end to end (inter-sweep gaps are not kept)..pxp: Igor Packed Experiment. Importable waves are listed by folder path (e.g.root/stims/HodgkinHuxley); one is selected automatically if it is the only one. Malformed records are skipped with a warning and logged..csv/.txt: comma, tab or whitespace separated; set Source sampling rate (Hz).- Input: one value per row, optional header with the waveform name.
- Output: one trace per column, optional header row with unique trace names. All columns are signals (remove any time column); rows must be complete and numeric. Columns get consecutive neuron IDs from the selected one.
The preview shows name, format, sample count, sample interval, units, value range and Igor note. Data keep their source sample interval: no resampling on import, so different rates coexist and align by time.
Import targets
Input dialog:
- Create new input array: name, type (Excitatory, Inhibitory, External), units; defaults come from the wave.
- Import into existing input array: pick array and Target neuron index. Extend target input array to fit imported duration (else overflow is cut); Replace target neuron values instead of adding to them (else values are added). Other neurons are untouched.
Output dialog:
- Create new trace data (experiment, name, neuron ID, units) or add to existing trace data (Target neuron ID, extend, replace an existing row).
- Detect spikes (current-clamp voltage only) stores detected spikes as spike data in the same experiment.
- Packed experiments: import as many waves as needed, then click Close.
If the target uses a different sample interval, NeuroSeq asks:
- Resample wave to target Δt (default): the target is unchanged.
- Remap target to wave Δt: the whole target moves to the wave's grid. Timing can shift by one sample, and a fast recording can make the target very large.
- Cancel.
Each import is one undoable edit.
Limitations
- One wave per import, also for
.pxp. - Sutter routine structure in packed experiments is not reconstructed, only the waves.
To export input arrays for SutterPatch, see Patch clamp export.