Experiments
Each simulation run or imported recording becomes a data group (an
Experiment) holding trace, spike and synapse data. Groups appear in the
Neuron data, Spike data, Synapse data and All data selectors of
the Data toolbar.
Manage Data
File → Manage Data lists every data group with its duration, description and data sets. Expand a group to see its data sets (traces, spikes, synapses) with their details (neurons, spikes, matrix size).
- Rename (or double-click a name) renames a data group or a single data
set. The new name appears in the Data toolbar selectors as
group :: data set. Names must be unique (data sets: per kind within the group) and cannot contain::. - Edit Description (or double-click the Description column) stores a free note on a data group, for example the slice or field of view.
- Delete Selected removes the selected data sets only, or, for a selected group, the whole group with all its data. Input arrays are never deleted here.
Renames, descriptions and deletions are undoable (Ctrl+Z) and saved in the
project file.
Generate synthetic data
File → Generate Synthetic Data... (Ctrl+G) creates test traces for
prototyping analyses. Each group has Export as a file and Add to the
project; Data Preview updates as you change parameters.
Patch clamp: pick a template in Select traces, the neurons in Indexes to import, Noise (mV) (default 0.5) and Output sampling rate (Hz) (default 1000).
Imaging: fluorescence driven by a spike pattern (Select spikes).
| Parameter | Default | Notes |
|---|---|---|
| Recording duration (s) | 10 | |
| Number of neurons | 10 | |
| F0 (photoelectrons) | 1000 | Baseline brightness, scaled per neuron by a lognormal (mean 0, sigma 0.25). |
| dF/F | 0.4 | Mean peak change for an isolated spike. |
| dF/F variability | 0.04 | |
| Indicator response | Exponential decay | Or Rise and decay (difference of exponentials). |
| Rise time constant (s) | 0.010 | Rise and decay only; must be shorter than the decay. Not the time to peak (about 20 ms with defaults). |
| Decay time (s) | 0.050 | |
| Sampling rate (Hz) | 30 | |
| Photoelectron noise factor | 1.0 | Shot-noise scaling. |
Overlapping spike responses add up. Responses are computed at 0.1 ms and then sampled, so a sampled trace can miss the exact peak.
Segmentation test data
To make a synthetic Cellpose image and matching segmentation from the command line:
Options are in Holographic stimulation.