Holographic stimulation

NeuroSeq uploads and runs .seq sequences on the HOLO4D two-photon holographic stimulation rig through SysCon2, which must run on the same Windows PC (local named pipe). Sequences come from Holography export.

Stimulation setup panel

View → Show Stimulation setup, tab SysCon2 (HOLO4D):

  • Connection: Connect / Disconnect.
  • Sequence Manager: Export with settings…; Export current array to stimulation setup re-exports the shown array with the last settings and its own Target power box (these scripts are temporary and deleted when NeuroSeq closes). Refresh, Select, Delete the sequences in SysCon2, or Browse… and Import a local .seq into the Target directory (default neuroseq\<date>).
  • Preview: collapsed by default (Show preview).
  • Holo4D: select the imported sequence, set Runs (0 = endless, asks for confirmation), Start condition and Trigger behavior under Advanced options, then Upload (waits for Idle) and Run. The panel shows Busy/Idle and elapsed time, not percent complete. A triggered run waits until Busy is seen. Stop also cancels a queued Run.
  • Laser: read-only. Get Status discovers the lightsources (preferring 940 nm). Set power, shutter and emission in SysCon2.

Dynamic input routines on the rig

Choose the SysCon2 (calcium imaging) target in the rheobase or STDP window dialog; Use SysCon2 dt fixes the array's timestep.

Hardware settings (SysCon2 / ScanImage) holds target power, laser, spiral scanning and 10 spots per cell (shared with the SysCon2 panel) and the recording options:

  • Run blocks automatically and record them with ScanImage (default on): each block is uploaded, run and recorded, and ΔF/F and spikes are extracted; see ScanImage acquisition. Rheobase counts a response when ΔF/F rises by the Response threshold (default 20 %) in the post-pulse window, or when OASIS finds a spike of at least the Spike threshold, depending on Calcium readout.
  • Unticked: each block is only imported into SysCon2. Run, record and import it yourself, then click Calcium data imported. Suite2p's normalised traces are refused for ΔF/F rise.

Safety limits: a block is refused without a target power above 0 mW and a LUT for the chosen laser, with a target above the LUT maximum, with amplitudes outside (0, 1], or with a stimulated neuron lacking a Cellpose ROI. Export warnings are asked once per routine.

Rheobase defaults on this target: 16.7 ms pulse (one spiral), up to 100 ms, 1 s recovery, 300 ms post-pulse window, Fixed duration, varying amplitude, 3 repeats per probe. Each target keeps its own values. With deconvolved spikes, a spike in the frame after the window still counts.

If the input array already holds input, Start offers Clear and start over, Continue after last input, or Start in new arrays (new empty array and data group named after the run, e.g. Exc_stimulation rheobase_2026-10-22_143012).

Each run saves its blocks in its own folder in the export folder, e.g. SysCon exports\rheobase_2026-10-22_143012\rheobase_2026-10-22_143012_001.seq (with PNG and sidecar), imported into SysCon2 under the same name.

Generating test data (CLI)

# 512 × 512 image with a 10 × 10 grid of cells
neuroseq --generate-cellpose-test-data ./cellpose_512.tif \
 --cellpose-grid-rows 10 --cellpose-grid-cols 10 \
 --cellpose-radius 11 --cellpose-gap 30

# 1300 × 1300 with auto-fitted radius and gap
neuroseq --generate-cellpose-test-data ./cellpose_1300.tif \
 --cellpose-grid-rows 10 --cellpose-grid-cols 10 \
 --cellpose-square-size 1300